Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio2.unb.br/jspui/handle/10482/30289
Arquivos associados a este item:
Arquivo TamanhoFormato 
ARTIGO_UltrasoundImagingWomen.pdf1,47 MBAdobe PDFVisualizar/Abrir
Título: Ultrasound imaging in women's arm flexor muscles : intra-rater reliability of muscle thickness and echo intensity
Autor(es): Vieira, Amilton
Siqueira, Angelina Freitas
Ferreira Júnior, João B.
Pereira, Paulo
Wagner, Dale
Bottaro, Martim
Assunto: Ultrassonografia
Reabilitação
Hipertrofia muscular
Data de publicação: Nov-2016
Editora: Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
Referência: VIEIRA, Amilton et al. Ultrasound imaging in women's arm flexor muscles: intra-rater reliability of muscle thickness and echo intensity. Brazilian Journal of Physical Therapy, São Carlos, v. 20, n. 6, p. 535-542, nov./dez. 2016. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552016000600535&lng=en&nrm=iso>. Acesso em: 4 jan. 2018. Epub Sep 22, 2016. doi: http://dx.doi.org/10.1590/bjpt-rbf.2014.0186.
Abstract: Background Different ultrasound parameters have been frequently used to assess changes associated with training, aging, immobilization, and neuromuscular diseases. However, an exploratory reliability analysis of the echo intensity (EI) and muscle thickness (MT) of the forearm flexors is scarce, especially in women. Objective The purpose of the present study was to determine the intra-rater reliability of MT and EI assessed by ultrasound in young women. Method Ultrasonographic MT and EI were acquired in the forearm flexors of 41 young women (22±2 yrs). Reliability was calculated using intraclass correlation coefficient (ICC2,1), standard error of measurement (SEM), coefficient of variation (CV), smallest detectable change (SDC), and Bland and Altman plot analysis. Results ICC values for MT and EI were 0.88 (95% CI: 0.78-0.93). The SEM and CV values were lower than 10%. Bland and Altman analysis revealed that ultrasound mean differences were 0.27 mm (Limits of Agreement - LOA 95%: - 2.6 to 3.2 mm) and -0.09 a.u. (LOA 95%: - 10.9 to 10.7 a.u.). Conclusion MT and EI assessed by ultrasonography in young women appear to be reliable and may be used to monitor changes in muscle mass induced by strength training when these changes exceed the precision of ultrasound.
Unidade Acadêmica: Faculdade de Educação Física (FEF)
Licença: Brazilian Journal of Physical Therapy - This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited (CC BY 4.0). Fonte: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552016000600535&lng=en&nrm=iso. Acesso em: 4 jan. 2018.
DOI: http://dx.doi.org/10.1590/bjpt-rbf.2014.0186
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro completo do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.